Verwold, ChadOrtega-Hernandez, AlejandroMurakami, JillianPatterson-Fortin, LauraBoutros, JennySmith, RichardKimura, Susana Y.2023-02-062023-02-062021-06-23Verwold, C., Ortega-Hernandez, A., Murakami, J., Patterson-Fortin, L., Boutros, J., Smith, R., & Kimura, S. Y. (2021). New iodine-based electrochemical advanced oxidation system for water disinfection: Are disinfection by-products a concern? Water Research, 201, 117340. https://doi.org/10.1016/j.watres.2021.117340http://hdl.handle.net/1880/115815A novel electrochemical Advanced Oxidation System (AOS) has been recently developed for water disinfection where iodide is used to generate active iodine species in-situ. However, the presence of iodide during water disinfection can lead to the formation of iodinated disinfection byproducts (I-DBPs), which have been shown to be more cyto- and genotoxic than their chlorinated and brominated analogs. In this study, the formation of DBPs was assessed in ultrapure water, river water and secondary wastewater effluents treated by the AOS. A comprehensive total organic halogen and target DBP analysis was used that included 25 unregulated DBPs, and the total organic halogen (TOX) quantified as total organic chlorine (TOCl), total organic bromine (TOBr), and total organic iodine (TOI). Ultrapure water disinfection only quantified iodoform (TIM) at a maximum concentration of 0.90 ± 0.05 µg/L. River water results show that TOI increase from 1.3 ± 0.3 µg/L before disinfection (t=0) to a maximum of 3.5 ±1.1 µg/L. TIM and bromodiiodomethane (BDIM) were the only targeted iodo-trihalomethanes (I-THMs) that were quantified with a maximum total I-THM concentration of 0.44 µg/L. Secondary wastewater effluent disinfection results show that TOI increased from 1.8 ± 0.3 µg/L (t=0) to a maximum concentration of 35.3 ± 0.3 µg/L. Iodide and iodate were the main iodinated species exiting the AOS system with a iodine recovery of 94-101%. The results from this study show that the AOS formed low levels of iodinated DBPs in treated water sources that are comparable to the levels found in disinfected drinking water and wastewater.engUnless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.Disinfection by-productsNew Iodine-based Electrochemical Advanced Oxidation System for Water Disinfection: Are Disinfection By-products a Concern?