Show simple item record

dc.contributor.advisorFrayne, Richard
dc.contributor.authorSabati, Mohammad
dc.date.accessioned2005-08-16T17:22:11Z
dc.date.available2005-08-16T17:22:11Z
dc.date.issued2004
dc.identifier.citationSabati, M. (2004). Interactive large field-of-view peripheral magnetic resonance angiography (Unpublished doctoral thesis). University of Calgary, Calgary, AB. doi:10.11575/PRISM/17314en_US
dc.identifier.isbn0494046147en
dc.identifier.urihttp://hdl.handle.net/1880/41949
dc.descriptionBibliography: p. 212-231en
dc.description.abstractA novel interactive technique for whole-body magnetic resonance (MR) imaging and lower limb angiography was developed. This approach scans an extended or large field­of-view (FOY) which may potentially allow imaging of the entire human body in a single MR procedure. Large FOV images were acquired by continuously and interactively moving the patient table through the scanner during data acquisition. A real-time MR system was developed to allow rapid visual feedback to the scanner operator thus enabling a fully interactive, fast, and patient-friendly approach to imaging. This technique was termed "Interactive Large Field-of-View Magnetic Resonance Imaging" and when correctly implemented allowed one to acquire an extended seamless volume (3D) image of the entire human body in a few minutes. When performed in conjunction with a single injection of an MR contrast agent, the interactive large FOV MR imaging approach allows acquisition of a high-resolution 3D study of the entire peripheral vasculature (i.e., vessels inferior to the renal arteries). These large angiograms are acquired by following the injected contrast agent dynamics in real­time and moving the patient table accordingly, in a fashion that is analogous to a conventional X-ray run-off study but without any of the risks and limitations associated with the X-ray-based imaging. The proposed imaging method introduces a new category to the arsenal of currently available approaches for performing peripheral MR angiography (MRA); a single­station/single-injection approach. Single-station/single-injection approaches will be of great benefit to patients with peripheral vascular diseases, as they will allow a quick, non­invasive, and friendly assessment of these diseases. This thesis establishes and provides evidence in support of interactive large FOV MR imaging by: . Performing theoretical development and simulations of the method, 2. Proposing novel undersampling data acquisition strategies that are necessary for limited-time contrast-enhanced acquisitions, 3. Identifying the challenges and discovering solutions to the technical and engineering issues preventing implementation of the interactive real-time large FOV MR imaging approach on a clinical MR scanner, 4. Investigating the data acquisition, processing, and reconstruction challenges in the proposed approach and presenting robust and effective solutions, and 5. Evaluating the feasibility and the functionality of the proposed technique on phantoms and humans. At the conclusion of this dissertation, I have addressed these issues and demonstrated a "proof-of-concept" for the interactive large FOV approach in whole-body MR imaging as well as in peripheral MRA.
dc.format.extentxxiii, 239 leaves : ill. ; 30 cm.en
dc.language.isoeng
dc.rightsUniversity of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
dc.titleInteractive large field-of-view peripheral magnetic resonance angiography
dc.typedoctoral thesis
dc.publisher.institutionUniversity of Calgaryen
dc.identifier.doihttp://dx.doi.org/10.11575/PRISM/17314
thesis.degree.nameDoctor of Philosophy
thesis.degree.namePhD
thesis.degree.disciplineElectrical and Computer Engineering
thesis.degree.grantorUniversity of Calgary
dc.identifier.lccAC1 .T484 2004 S3255en
dc.publisher.placeCalgaryen
ucalgary.thesis.notesUARCen
ucalgary.thesis.uarcreleaseyen
ucalgary.item.requestcopytrue
ucalgary.thesis.accessionTheses Collection 58.002:Box 1534 520492051


Files in this item

Thumbnail
Embargoed until: 2200-01-01

This item appears in the following Collection(s)

Show simple item record

University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.