The negative BOLD response as a marker of the seizure onset zone

dc.contributor.advisorFederico, Paolo
dc.contributor.authorDykens, Perry Everett
dc.contributor.committeememberGoodyear, Brad
dc.contributor.committeememberKlein, Karl Martin
dc.date.accessioned2023-09-28T17:06:07Z
dc.date.available2023-09-28T17:06:07Z
dc.date.issued2023-09-20
dc.description.abstractEpilepsy is a neurological disease affecting 70 million people worldwide. For most individuals, these seizures can be controlled using medications, however nearly 1 in 3 people may need surgery to achieve seizure freedom. For this surgery to be successful, the brain region generating the seizures, which contains the critical seizure onset zone (SOZ), must be accurately identified and removed. Unfortunately, the surgical success rate is low likely due to imprecise determination of the SOZ. As a novel approach to SOZ identification, the collection of intracranial electroencephalography and functional magnetic resonance imaging (iEEG-fMRI) has been proposed as a novel method of identifying the SOZ. However, iEEG-fMRI faces the methodological challenge of artifact introduced from MR scanning which completely obscures the physiological EEG signal. Therefore, the first step towards bringing iEEG-fMRI into the clinical realm is to improve methods for extracting the physiological EEG signal from the iEEG-fMRI data. To this end, the first study in this thesis validated a set of methods aimed at removing fMRI artifact from iEEG, culminating in the creation of the first automatic iEEG pre-processing pipeline. The next step towards clinical utility for iEEG-fMRI is improving our interpretation of iEEG-fMRI results. Traditionally, only positive IED related fMRI activation maps were considered in relation to SOZ localization, and the negative response was ignored. It has been suggested that both positive and negative activation maps should be considered, and the maximal cluster of these two maps, regardless of polarity, should be used to localize the SOZ. In the second study, the concept was tested using iEEG-fMRI and it was found that the use of the maximal negative cluster had limited utility for SOZ localization. The results of this thesis provide a new method for preparing EEG data from iEEG-fMRI experiments and it shows that the bulk of maximal negative fMRI clusters have limited reliability for clinical applications.
dc.identifier.citationDykens, P. E. (2023). The negative BOLD response as a marker of the seizure onset zone (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.
dc.identifier.urihttps://hdl.handle.net/1880/117174
dc.identifier.urihttps://doi.org/10.11575/PRISM/42016
dc.language.isoen
dc.publisher.facultyCumming School of Medicine
dc.publisher.institutionUniversity of Calgary
dc.rightsUniversity of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
dc.subjectepilpesy
dc.subjectintracranial electroencephalography
dc.subjectinterical epiltiform discharges
dc.subjectgradient switching artifact
dc.subjectfMRI
dc.subjectEEG
dc.subjectEEG-fMRI
dc.subjectBOLD
dc.subjectIEDs
dc.subjectNegative BOLD
dc.subject.classificationNeuroscience
dc.titleThe negative BOLD response as a marker of the seizure onset zone
dc.typemaster thesis
thesis.degree.disciplineMedicine – Neuroscience
thesis.degree.grantorUniversity of Calgary
thesis.degree.nameMaster of Science (MSc)
ucalgary.thesis.accesssetbystudentI do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible.
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ucalgary_2023_dykens_perry.pdf
Size:
2.5 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.62 KB
Format:
Item-specific license agreed upon to submission
Description: