MICRO-FLAME PHOTOMETRIC DETECTION IN MINIATURE GAS CHROMATOGRAPHY ON A TITANIUM TILE

dc.contributor.authorMcKelvie, Kaylan H.
dc.contributor.authorThurbide, Kevin B.
dc.date.accessioned2019-06-13T14:49:37Z
dc.date.available2019-06-13T14:49:37Z
dc.date.issued2019-06-12
dc.description.abstractA novel miniaturized gas chromatography - flame photometric detection device built within a titanium platform (Ti µGC-FPD) is presented. The 7.5 cm x 15 cm monolithic Ti device contains both an OV-101 coated separation column (5 m x 100 µm i.d.) and a shielded cavity to house the hydrogen-rich detector flame. The FPD employs a micro counter-current flame (about 250 µm in diameter) that is stabilized by opposing relatively low flows of oxygen and hydrogen (7-10 mL/min O2 and 40 mL/min H2). Under optimal conditions, the minimum detectable limits are about 70 pg S/s for sulfur and 8 pg P/s for phosphorous. The natural (i.e. unfiltered) selectivity for these responses over carbon is near 104.3 for S/C and 105 for P/C. Even greater selectivity over hydrocarbons can further still be obtained by employing conventional interference filters. Overall, good separations with stable and sensitive detector performance are obtained with the device, and its sturdy Ti structure supports robust operation. Results indicate that this Ti µGC-FPD device may be a useful alternative approach for incorporating selective FPD sensing in µGC analyses.en_US
dc.description.grantingagencyNatural Sciences and Engineering Research Council - Collaborative Research & Development Granten_US
dc.identifier.citationMcKelvie, K. H., & Thurbide, K. B. (2019). MICRO-FLAME PHOTOMETRIC DETECTION IN MINIATURE GAS CHROMATOGRAPHY ON A TITANIUM TILE. 1-26. https://doi.org/10.1007/s10337-019-03723-yen_US
dc.identifier.doihttps://doi.org/10.1007/s10337-019-03723-yen_US
dc.identifier.urihttp://hdl.handle.net/1880/110496
dc.publisher.facultyScienceen_US
dc.publisher.hasversionPost-printen_US
dc.rightsUnless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.en_US
dc.titleMICRO-FLAME PHOTOMETRIC DETECTION IN MINIATURE GAS CHROMATOGRAPHY ON A TITANIUM TILEen_US
dc.typeunknown
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
McKelvie Thurbide Second Revised Manuscript.docx
Size:
2.08 MB
Format:
Microsoft Word
Description:
main article
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.92 KB
Format:
Item-specific license agreed upon to submission
Description: