Improved Cavitation Monitoring and Detection Methods for Focused Ultrasound Blood-Brain Barrier Disruption

dc.contributor.advisorCuriel, Laura
dc.contributor.authorKhan, Sonia
dc.contributor.committeememberCuriel, Laura
dc.contributor.committeememberSmith, Michael
dc.contributor.committeememberFear, Elise
dc.contributor.committeememberAbbasi, Zahra
dc.date2022-02
dc.date.accessioned2022-01-25T16:43:15Z
dc.date.available2022-01-25T16:43:15Z
dc.date.issued2022-01
dc.description.abstractTranscranial focused ultrasound (FUS) in combination with microbubbles has demonstrated promising outcomes in treatment of brain disorders by stimulating transient BBB disruption, allowing therapeutics to enter into the brain. Currently, time signals from a hydrophone are transformed into frequency domain to monitor cavitation activity during BBB opening. The area under the curve (AUC) in a 300 Hz bandwidth around the subharmonic is used as a metric to determine cavitation activity. However, given the available frequency resolution, there are very few points within the 300 Hz bandwidth for precisely analysing the AUC. Also, many recorded signals show no detectable subharmonic above the noise as the A/D calibration is overwhelmed due to the strong fundamental. These issues can result in the subject being under treated or over treated. This research aims to better monitor and control the cavitation phenomenon for BBB disruption by developing methods to improve the cavitation spectra. The acoustic signals captured by a hydrophone from the excited microbubble phantom were filtered with a low pass analog filter to improve the system’s dynamics of self-calibration by suppressing the strong fundamental. The acoustic signals were further improved with two proposed signal processing techniques, namely, Fourier interpolation via zero-padding to increase the spectral frequency resolution, and windowing, which allowed us to uncover previously unreported subharmonic side lobes. Additionally, we propose the bandwidth to be wider than the current 300 Hz for AUC to include the useful information in these side bands. Our proposed improvements were validated on animal data. Finally, the performance of our proposed improvements was compared to traditional methods by evaluating metrics for cavitation detection. Previous studies reported a steady increase in the AUC with increase in pressure, whereas our work presented that the AUC would rise drastically at the stable cavitation threshold indicating that maximum energy is concentrated in stable cavitation regime. Then, beyond this threshold, the AUC will drop before rising again, signifying the energy shift towards initiating inertial cavitation. Our findings can be beneficial to enhance cavitation detection metrics and we can actually visualize the different cavitation regimes when the AUC and power are evaluated for subharmonic.en_US
dc.identifier.citationKhan, S. (2022). Improved cavitation monitoring and detection methods for focused ultrasound Blood-brain barrier disruption (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.en_US
dc.identifier.doihttp://dx.doi.org/10.11575/PRISM/39542
dc.identifier.urihttp://hdl.handle.net/1880/114330
dc.language.isoengen_US
dc.publisher.facultySchulich School of Engineeringen_US
dc.publisher.institutionUniversity of Calgaryen
dc.rightsUniversity of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.en_US
dc.subjectMicrobubblesen_US
dc.subjectInterpolationen_US
dc.subjectWindowingen_US
dc.subjectArea under the curve (AUC)en_US
dc.subjectHarmonic frequency componentsen_US
dc.subject.classificationEngineering--Biomedicalen_US
dc.subject.classificationEngineering--Electronics and Electricalen_US
dc.titleImproved Cavitation Monitoring and Detection Methods for Focused Ultrasound Blood-Brain Barrier Disruptionen_US
dc.typemaster thesisen_US
thesis.degree.disciplineEngineering – Electrical & Computeren_US
thesis.degree.grantorUniversity of Calgaryen_US
thesis.degree.nameMaster of Science (MSc)en_US
ucalgary.item.requestcopytrueen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ucalgary_2022_khan_sonia.pdf
Size:
4.75 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.62 KB
Format:
Item-specific license agreed upon to submission
Description: