Needle and Potentiostat Study for Blood Glucose Monitoring: Third-Generation E-Mosquito

dc.contributor.advisorMintchev, Martin P.
dc.contributor.advisorYadid-Pecht, Orly
dc.contributor.authorTeixeira de Carvalho Rojas, Jonas
dc.contributor.committeememberNielsen, Jorgen
dc.contributor.committeememberCuriel, Laura
dc.contributor.committeememberSmith, Michael Richard
dc.date2020-06
dc.date.accessioned2020-03-06T16:33:40Z
dc.date.available2020-03-06T16:33:40Z
dc.date.issued2020-03-04
dc.description.abstractDiabetes Mellitus is a lifelong condition related to the inability of the pancreas to produce insulin, a hormone that regulates glucose levels in the body. Diabetes can also occur when the body resists the effects of the insulin. If diabetes is not treated properly or in time, the consequences can be severe and will put the patient’s life at risk. To control the glucose levels in their body, patients perform self-managed treatments. The objective of these treatments is to normalize the glucose levels by continuously monitoring the blood. Due to their high-accuracy in displaying real-time glucose concentration in the blood, finger pricking tests have become the most popular method to monitor the glucose levels. However, the finger prick method remains inconvenient for the patient. This is due to the technique, which demands the user to stab themself with a needle (inflicting pain) to access a blood sample. As a consequence, a significant number of patients drop their treatments. E-Mosquito is a new concept: a minimally-invasive glucose monitor meant to replace the finger pricking test. The second-generation E-Mosquito has proven to be an effective device to access a blood sample without inflicting pain to the user. Additionally, the E-Mosquito also has a glucometer that matches the accuracy of its commercial counterparts. Nevertheless, the E-Mosquito still requires some adjustments to acquire the correct amount of blood with a high success rate. The glucometer also requires improvement to avoid noise insertion in the circuit, that could influence the glucose readings. This thesis aims to optimize the E-Mosquito’s efficiency with two different studies. The first study focuses on selecting an appropriate needle to increase the success rate and the amount of blood acquired from the patient without inflicting pain. Furthermore, changes in the E-Mosquito design were performed to adjust the SMA actuator used in the blood acquisition. The second study is the addition of a new programmable electrochemical potentiostat. This addition reduces the number of components integrating the glucometer and maximize the accuracy of the glucose detection in the E-Mosquito when evaluating a blood sample. In the needle study, six out of eight tests extracted the required amount of blood, meaning that the success rate increased 25% for blood samples <10µL. The electrochemical potentiostat study shows that the new chip reduces the number of components inside the E-Mosquito, from three to just one, without affecting its accuracy. The glucometer exhibited a good linear correlation (R=0.9728). This complies with the standards set by the Food and Drug Administration. The two studies increase the feasibility of the E-Mosquito to replace the current glucose monitor devices.en_US
dc.identifier.citationTeixeira de Carvalho Rojas, J. (2020). Needle and Potentiostat Study for Blood Glucose Monitoring: Third-Generation E-Mosquito (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.en_US
dc.identifier.doihttp://dx.doi.org/10.11575/PRISM/37628
dc.identifier.urihttp://hdl.handle.net/1880/111718
dc.language.isoengen_US
dc.publisher.facultySchulich School of Engineeringen_US
dc.publisher.institutionUniversity of Calgaryen
dc.rightsUniversity of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.en_US
dc.subjectE-Mosquitoen_US
dc.subjectBGMen_US
dc.subjectGlucoseen_US
dc.subjectDiabetesen_US
dc.subject.classificationEducation--Healthen_US
dc.subject.classificationEducation--Sciencesen_US
dc.subject.classificationEducation--Technologyen_US
dc.subject.classificationBiophysics--Medicalen_US
dc.subject.classificationEngineering--Biomedicalen_US
dc.subject.classificationEngineering--Electronics and Electricalen_US
dc.subject.classificationEngineering--Mechanicalen_US
dc.titleNeedle and Potentiostat Study for Blood Glucose Monitoring: Third-Generation E-Mosquitoen_US
dc.typemaster thesisen_US
thesis.degree.disciplineEngineering – Electrical & Computeren_US
thesis.degree.grantorUniversity of Calgaryen_US
thesis.degree.nameMaster of Science (MSc)en_US
ucalgary.item.requestcopytrueen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ucalgary_2020_teixeira-de-carvalho-rojas_jonas.pdf
Size:
3.61 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.62 KB
Format:
Item-specific license agreed upon to submission
Description: