dc.description.abstractGeometry of the patella (kneecap) remains poorly understood yet is highly relevant to performing the correct patellar cut to reduce pain and to improve function and satisfaction after knee replacement surgery. Although studies routinely refer to “parallel to the anterior surface” and “the patellar horizon,” a quantitative definition of these is lacking and significant variability exists between observers for this irregularly-shaped bone. A 2D-3D shape analysis technique was developed to determine the optimal device configuration for contacting the patellar surface. Axial and sagittal pseudo-X-rays were created from 18 computed tomography (CT) scans of cadaveric knees. Four expert surgeons reviewed three repetitions of the X-rays in randomized order, marking their desired cut plane and their estimate of the anterior surface. These 2D results were related back to the 3D model to create the desired plane. There was considerable variability in perceptions, with intra- and intersurgeon repeatability (standard deviations) ranging from 1.3° to 2.4°. The best configuration of contact points to achieve the desired cutting plane was three pegs centred on the patellar surface, two superior and one inferior, forming a 16 mm equilateral triangle. This configuration achieved predicted cut planes within 1° of the surgeon ranges on all 18 patellae. Implementing this, as was done in a subsequent prototype surgical device, should help improve the success and satisfaction of knee replacement surgery.
dc.description.versionPeer Reviewed
dc.identifier.citationE. L. Rex, J. Werle, B. C. Burkart, J. R. MacKenzie, K. D. Johnston, and C. Anglin, “Shape Analysis of the Patellar Bone Surface and Cutting Plane for Knee Replacement Surgery,” Computational and Mathematical Methods in Medicine, vol. 2018, Article ID 6490425, 9 pages, 2018. doi:10.1155/2018/6490425
dc.identifier.doihttp://dx.doi.org/10.11575/PRISM/33231
dc.identifier.urihttp://dx.doi.org/10.1155/2018/6490425
dc.identifier.urihttp://hdl.handle.net/1880/108927
dc.language.rfc3066en
dc.rights.holderCopyright © 2018 E. L. Rex et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
dc.titleShape Analysis of the Patellar Bone Surface and Cutting Plane for Knee Replacement Surgery
dc.typeJournal Article
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CMMM.2018.6490425.pdf
Size:
2.23 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description: