Importance of Reference Muscle Selection in Quantitative Signal Intensity Analysis of T2-Weighted Images of Myocardial Edema Using a T2 Ratio Method

dc.contributor.authorCarbone, Iacopo
dc.contributor.authorChilds, Helene
dc.contributor.authorAljizeeri, Ahmed
dc.contributor.authorMerchant, Naeem
dc.contributor.authorFriedrich, Matthias G.
dc.date.accessioned2018-09-27T11:26:35Z
dc.date.available2018-09-27T11:26:35Z
dc.date.issued2015-06-21
dc.date.updated2018-09-27T11:26:34Z
dc.description.abstractObjectives. The purpose of our study was to identify the suitability of various skeletal muscles as reference regions for calculating the T2 SI ratio for a semiautomated quantification of the extent of myocardial edema with T2-weighted images. Methods. Thirty-four patients with acute myocardial infarction (MI) were enrolled. The extent of myocardial edema was determined by T2 SI ratio map, using 4 different muscles as reference: major and minor pectoralis, serratus anterior, teres minor-infraspinatus, and subscapularis. The size of myocardial edema as visually quantified was used as the standard of truth. The control group consisted of 15 patients with chronic MI. Intra- and interobserver variability were assessed. Results. Due to poor image quality four patients were excluded from the analysis. In acute MI patients, serratus anterior muscle showed the strongest correlation with the visual analysis (; ) and low inter- and intraobserver variability, while the other muscles resulted in a significant interobserver variability. In contrast, the use of other muscles as a reference led to overestimating edema size. Conclusions. In acute MI patients, serratus anterior resulted to be the most reliable and reproducible muscle for measuring the extent of myocardial edema.
dc.description.versionPeer Reviewed
dc.identifier.citationIacopo Carbone, Helene Childs, Ahmed Aljizeeri, Naeem Merchant, and Matthias G. Friedrich, “Importance of Reference Muscle Selection in Quantitative Signal Intensity Analysis of T2-Weighted Images of Myocardial Edema Using a T2 Ratio Method,” BioMed Research International, vol. 2015, Article ID 232649, 9 pages, 2015. doi:10.1155/2015/232649
dc.identifier.doihttps://doi.org/10.1155/2015/232649
dc.identifier.urihttp://hdl.handle.net/1880/108150
dc.language.rfc3066en
dc.rights.holderCopyright © 2015 Iacopo Carbone et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
dc.titleImportance of Reference Muscle Selection in Quantitative Signal Intensity Analysis of T2-Weighted Images of Myocardial Edema Using a T2 Ratio Method
dc.typeJournal Article
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
BMRI.2015.232649.pdf
Size:
3.24 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description: